PRODUCTS

Search for the instrument you want

 

Walk-in Constant Temperature and Humidity Test Chamber-HYHW-8C

Walk-in Constant Temperature and Humidity Test Chamber

HYHW-8C

1. Scope of application It is suitable for high and low temperature tests, damp and heat tests on electrical, electronic, mechanical and other products, parts and materials, and quality and reliability testing of products, parts and materials under simulated temperature and humidity changes. 2. Meet the standards Requirements of GB5170, 2, 5-2008 "Basic parameter verification methods for environmental testing equipment for electrical and electronic products: Low temperature, high temperature, constant humidity and heat, and alternating humidity and heat testing equipment"; GB/T 2423.1-2008 "Basic Environmental Test Procedures for Electrical and Electronic Products - Test A: Low Temperature Test Method"; GB/T 2423.2-2008 "Basic Environmental Test Procedures for Electrical and Electronic Products - Test B: High Temperature Test Method"; GB/T 2423.3-2016 "Basic Environmental Test Procedures for Electrical and Electronic Products - Test Ca: Constant Humidity and Heat Test Method"; GB/T 2423.4-2008 "Basic Environmental Test Procedures for Electrical and Electronic Products - Test Db: Alternating Humid Heat Test Method"; GB/T 2423.22-2012 "Basic Environmental Test Procedures for Electrical and Electronic Products - Test N Temperature Change Test Method"; GB/T 5170.2-2008 "Temperature Test Equipment"; GB/T 5170.5-2008 "Damp and Heat Test Equipment"; GB/T 10592-2008 "Technical Conditions for High and Low Temperature Test Chambers"; GB/T 10589-2008 "Technical Conditions for Low Temperature Test Chamber"; GB/T 10586-2006 "Technical Conditions for Humid Heat Test Chamber"; GJB 150.3A-2009 "Military Equipment Laboratory Environmental Test Methods Part 3: High Temperature Test"; GJB 150.4A-2009 "Military Equipment Laboratory Environmental Test Methods Part 4: Low Temperature Test"; GJB 150.9A-2009 "Military Equipment Laboratory Environmental Test Methods Part 9: Damp Heat Test"; GB/T 11158-2008 "Technical Conditions for High Temperature Test Chamber"

Double-layer Explosion-Proof Test Chamber-HYH-B-900C

Double-layer Explosion-Proof Test Chamber

HYH-B-900C

1. Scope of application It is suitable for high and low temperature tests, damp and heat tests on electrical, electronic, mechanical and other products, parts and materials, and quality and reliability testing of products, parts and materials under simulated temperature and humidity changes. 2. Meet the standards GBT2423.4-2008 "Environmental Testing of Electrical and Electronic Products-Alternating Humidity and Heat Test Method" GB/T 2423.1-2008 "Environmental Testing of Electrical and Electronic Products - Test A Low Temperature Test Method" GB/T 2423.2-2008 "Environmental testing of electrical and electronic products - Test B High temperature test method" GJB150.3A-2009 "Military Equipment Laboratory Environmental Test Methods High Temperature Test" GJB150.4A-2009 "Military Equipment Laboratory Environmental Test Methods - Low Temperature Test" GB/T 10586-2006 "Technical Conditions for Humid Heat Test Chamber" GB/T 10592-2008 "Technical Conditions for High and Low Temperature Test Chambers" GB/T 5170.2-2017 "Inspection Methods for Environmental Test Equipment Part 2: Temperature Test Equipment" GB/T 5170.5-2016 "Inspection Methods for Environmental Test Equipment for Electrical and Electronic Products Part 5 Moisture and Heat Test Equipment" GB/T 36276 "Lithium-ion batteries for electric energy storage" GB/T 18135-2008 "Electrical Engineering CAD Drawing Rules" GB/T 18656-2002 "Identification of terminals in industrial systems, devices and equipment, and industrial product systems" GB/T23371.3-2009 "Basic Rules for Graphical Symbols for Electrical Equipment Part 3: Application Guidelines" GB/T 18517-2012 "Refrigeration Terminology" DB31/836-2014 "General Technical Principles for the Use of Refrigerants" GB/T 23681-2009 "Refrigeration system and heat pump system flow diagram and piping instrument diagram drawing and symbols" GB/T 50274-2010 "Code for construction and acceptance of installation projects of refrigeration equipment

Environmental Temperature Humidity Test Chamber-HYH-150

Environmental Temperature Humidity Test Chamber

HYH-150

1. Product Usage: It is suitable for high and low temperature test, damp heat test for electrical, electronic, mechanical and other products, partsand materials, quality and reliability test for products, parts and materials under simulated temperature andhumiditychanges. 2. Design reference stanfard: Requirements of GB5170, 2, 5-2008 "Testing methods for basic parameters of environmental testing equipment forelectricaland electronic products: Low temperature, high temperature, constant damp heat, alternating damp heat test equipment";Basic environmental test procedures for electrical and electronic products Test A: Low temperature test methodGB2423.1-2008 Basic environmental test procedures for electric and electronic products Test B: High temperature test methodGB2423.2-2008 Basic environmental test procedures for electric and electronic products Test Ca: Constant damp heat test methodGB/T2423.3-2008 Basic environmental test procedures for electrical and electronic products Test Db: Alternating damp heat testmethodGB/T423.4-2008 Basic environmental test procedures for electric and electronic products Test N Temperature change test methodGB/T2423.22-2002 GB/T 5170.2-2008 "Temperature Test Equipment" GB/T 5170.5-2008 "Damp heat test equipment" GB/T 10592-2008 "Technical Conditions of High and Low Temperature Test Chamber" GB/T 10589-2008 "Technical Conditions of Low Temperature Test Chamber" GB/T 10586-2006 "Technical Conditions of Humidity and Heat Test Chamber"

High Temperature Aging Room-HY

High Temperature Aging Room

HY

1、the scope of application It is suitable for high and low temperature test, damp heat test, and quality and reliability test of products, parts and materials under the conditions of temperature and humidity change for electrician, electronics, machinery and other products, parts and materials. 2、meet the standard GB/T 2423.2-2001 "Environmental testing of electrical and electronic products" Part 2: Test methods Test B: High temperature GB/T 3797-2005 "Electrical Control Equipment" JB/T 6174-1992 "Instrument function circuit board aging process specification" GB/T11158-2008 "Technical conditions for high temperature test chamber" 3、the box structure 3.1thermal insulation structure: Insulation material: double-sided galvanized steel sheet, surface spray treatment,Box insulation material: glass fiber rock wool board to ensure sealing . Ground: no treatment Insulation coefficient: 0.0028 W / (M.k) - watt / (section. temperature difference) 3.2Laboratory standard configuration Observation window: 1 transparent tempered glass hollow tempered glass (located on the door) Each step-through lead hole: φ100mm1 (the site is opened according to the customer's needs) Sample holder: 6 Explosion-proof energy-saving lamp 9W*4PCS Moving casters: none 3.3gate The door is equipped with two double-sided conductive multi-layer hollow glass windows, the material is the same as the library body (W1000*H1800*D50mm) 1 lighting lamp on the door observation window 3.4control panel Temperature control display, over temperature protection setting device, emergency stop switch, operation indicator, fault indicator, buzzer 3.5Mechanical room The mechanical room contains: draining device, fan, power distribution control cabinet 3.6distribution control :Cooling fan cabinet:Switchboard,Sample test terminal,Total power leakage circuit breaker 3.7heater:Nichrome electric wire heater Heater control mode: non-contact and other periodic pulse width adjustment, SSR (solid state relay)

High and low temperature test chamber for battery cell testing-

High and low temperature test chamber for battery cell testing

High and low temperature test chamber for battery cell testing 1. Product Description: The high and low temperature test chamber for electric core is used to test the safety of various batteries (electric vehicle batteries, UPS batteries, energy storage batteries, lead-acid batteries, power tool batteries, starter batteries, etc.) under different ambient temperatures for storage, overcharge and over-discharge, charging and discharging. 2.Product advantages: (1) Observation window with anti-fog and anti-frost function, which is convenient for observing the specimen during the test. (2) PID + PWM principle of VRF (refrigerant flow control) technology to achieve low-temperature energy-saving operation (electronic expansion valve according to the thermal conditions of refrigerant flow servo control technology) low-temperature working conditions, the heater does not participate in the work. This way in low-temperature conditions, can realize a 30% reduction in energy consumption. (3) A variety of protection devices, no fuse switch, fuse, over-temperature protection, anti-dry burning protection, water shortage protection, liquid level protection, compressor over-pressure, overheating, over-current protection, emergency stop and other protection devices, so that the test is more safe and reliable. (4) Heating up, cooling down, the system is completely independent to improve efficiency, reduce testing costs, increase life, reduce the failure rate. 3. Meet the test method (standard): GB/T31484-2015, GB/T31486-2015, GBT 2423.4-2008, GJB150.3-1986, IEC, JIS , UN, UL, SAE, IEEE, ISO High and low temperature test chamber for electric core of ring instrument for flammable and explosive specimen reliability test, the equipment adopts the overall explosion-proof design including (1) Various safety detection systems 2) Passive safety protection devices 3) Active safety protection, which can fully guarantee the test safety. 4. Chamber structure: Inner box material: SUS304 # stainless